Vector Projection-based Sensorless Control of a SynRM Drive Including Self and Cross-Saturation
- Autori: Accetta A.; Cirrincione M.; Luna M.; Pucci M.; Sferlazza A.
- Anno di pubblicazione: 2022
- Tipologia: Contributo in atti di convegno pubblicato in volume
- OA Link: http://hdl.handle.net/10447/586630
Abstract
This paper presents a sensorless technique for SynRM drives that is based on a vector projection method and takes into consideration the magnetic saturation of the motor, both the self and the cross-saturation. The proposed method is based on the dynamic equation of the SynRM including saturation, rewritten in integral form, and does not involve any high-frequency carrier injection. The technique has been tested in numerical simulation and experimentally on a suitably developed test set-up. Experimental results show a correct behavior of the sensorless SynRM drive, properly accomplishing speed transients in a wide speed range, including low speed, still maintaining a good accuracy in the speed and position estimation.