Salta al contenuto principale
Passa alla visualizzazione normale.

ANGELO IOVANE

HIGH-RESOLUTION ULTRASONOGRAPHY (HRUS) OF THE MENISCAL CYST OF THE KNEE : OUR EXPERIENCE

  • Autori: SORRENTINO F; IOVANE A; NICOSIA A; VACCARI A; CANDELA F; CIMINO PG; MIDIRI M
  • Anno di pubblicazione: 2007
  • Tipologia: Articolo in rivista (Articolo in rivista)
  • OA Link: http://hdl.handle.net/10447/25216

Abstract

Purpose. This study was undertaken to assess the diagnostic accuracy of high-resolution ultrasonography (HRUS) in the detection of meniscal cysts. Materials and methods. Over a 2-year period, 1,857 patients underwent magnetic resonance imaging (MRI) of the knee for traumatic or degenerative disorders. All patients with MRI evidence of a meniscal cyst were studied by HRUS. HRUS was also performed on an equal number of patients without MRI evidence of meniscal cyst who were used as a control group. All HRUS examinations were conducted by a radiologist blinded to the MRI findings. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of HRUS were assessed with reference to MRI. All patients underwent surgery, and the resected masses were studied by histological examination. Results. MRI allowed identification of a meniscal cyst in 52 patients. HRUS enabled correct detection of the meniscal cyst in 49/52 cases. In the control group, HRUS excluded the presence of meniscal cysts in all cases. HRUS had a sensitivity, specificity, PPV and NPV of 94.23%, 100%, 100% and 94.54%, respectively, for the detection of meniscal cysts. Conclusions. HRUS is a fairly reliable technique in the detection, characterisation and differentiation of the different forms of meniscal cyst.