Mixed MHD convection and Tritium transport in fusion-relevant configurations
- Authors: CIOFALO M; DI MAIO PA; SPOSITO G; VELLA G
- Publication year: 2005
- Type: Articolo in rivista (Articolo in rivista)
- OA Link: http://hdl.handle.net/10447/13693
Abstract
Mixed MHD flow and Tritium transport were computed for a slender poloidal duct, representative of a DEMO HCLL blanket element. 2-D flow and temperature fields were computed in the duct’s cross section under the assumption of parallel, fully developed flow, while Tritium concentration C was found by solving a fully 3-D problem with simplifying assumptions at the duct’s ends. The spatial distribution of C depended on the intensity and direction of the forced flow. Significant peak factors were obtained if the net flow rate was so low that re-circulation occurred; C maxima were attained near the walls for upward flow, in the core region for downward flow.