Salta al contenuto principale
Passa alla visualizzazione normale.

ANTONINO OSCAR DI TOMMASO

Design and experimental characterization of a low-cost, real-time, wireless AC monitoring system based on ATmega 328P-PU microcontroller

  • Autori: M. Caruso ; A. O. Di Tommaso ; R. Miceli ; G. Ricco Galluzzo ; P. Romano ; G. Schettino ; F. Viola
  • Anno di pubblicazione: 2015
  • Tipologia: Proceedings
  • OA Link: http://hdl.handle.net/10447/172272

Abstract

This paper describes the development and experimental characterization of a real-time, low-cost, wireless AC monitoring system based on ATmega 328P-PU microcontroller. The proposed system is composed by a main brain for the acquisition and the processing of the data measured by smart meters. From the experimental tests discussed in this work it is demonstrated that the proposed system can monitor, with adequate accuracy, the working cycles of electrical loads in order to evaluate its energy consumption.