Breast multiparametric ultrasound: a single-center experience

  • Autori: Zarcaro, Calogero; Orlando, Alessia Angela Maria; Ferraro, Fabiola; Donia, Simona; Melita, Arianna; Micci, Giuseppe; Cannella, Roberto; Bartolotta, Tommaso Vincenzo
  • Anno di pubblicazione: 2024
  • Tipologia: Articolo in rivista
  • OA Link: http://hdl.handle.net/10447/648993

Abstract

Purpose: To evaluate the role of multiparametric ultrasound (mpUS) in the characterization of focal breast lesions (FBLs). Methods: This prospective study enrolled patients undergoing multiparametric breast ultrasound for FBLs. An experienced breast radiologist evaluated the following ultrasound features: US BI-RADS category, vascularization pattern (internal, vessels in rim and combined) and presence of penetrating vessels with each Doppler method (Color-Doppler, Power-Doppler, Microvascular imaging), strain ratio (SR) and Tsukuba score (TS) with Strain Elastography (SE), Emax, Emean, Emin and Eratio with 2D-shear wave elastography (2D-SWE). Core biopsy for all BI-RADS 4-5 FBLs and 24-month follow-up for all BI-RADS 2-3 FBLs were considered for standard of reference. The diagnostic performance was assessed with the area under curve (AUCs) and cut-off values were determined according to the Youden's index. Results: A total of 139 FBLs were included with 75/139 (53.9%) benign and 64/139 (46.1%) malignant FBLs. Internal vascularization patterns (p < 0.001), penetrating vessels (p < 0.001), TS 4-5 (p < 0.001) and all 2D-SWE parameters (p < 0.001) were significantly different between benign and malignant FBLs. The BI-RADS score provided an AUC of 0.876 (95% CI 0.810-0.926) for the diagnosis of malignant FBLs. Among the 2D-SWE measurements, an excellent diagnostic performance was observed for Emax with an AUC of 0.915 (95% CI 0.856-0.956) and Emean of 0.908 (95% CI 0.847-0.951). Optimal cutoff for the diagnosis of malignant FBLs were US BI-RADS > 3, Strain Ratio > 2.52, Tsukuba Score > 3, Emax > 82.6 kPa, Emean > 66.0 kPa, Emin > 54.4 kPa and Eratio > 330.8. Multiparametric ultrasound, particularly SWE, can improve specificity in the characterization of FBLs.